Safety of escalators and moving walks - Part 5: Replacement of existing escalators/moving walks in existing buildings

prEN 115-5

This European Standard specifies the safety rules for new escalators/moving walks replacing existing escalators/moving walks installed in existing buildings where, due to limitations enforced by building constraints, certain requirements of EN 115-1:2017 cannot be fully met. This standard shall only be used when replacing existing escalators/moving walks where structural constraints within an existing building make the installation of fully EN115-1:2017 compliant escalators/moving walks impossible. The escalator/moving walk installer must liaise with the customer and recommend altering the building structure in the first instance and deviations from EN115-1 should only be considered as a last resort. This standard addresses a number of these constraints, gives requirements for alternative solutions and covers:  the replacement of an existing escalator/moving walk by a new one in an existing building. This standard does not cover:  construction and installation of a new escalator / moving walk in  an existing building, which is not replacing an existing escalator/moving walk;  replacement or modifications of some parts of existing escalator/moving walk, e.g. intruss modernization;  major modifications of existing escalator/moving walk, e.g. change of the location (see EN 115-1:2017, Annex L);  other applications outside of the scope of EN 115-1:2017

Abstract

This European Standard specifies the safety rules for new escalators/moving walks replacing existing escalators/moving walks installed in existing buildings where, due to limitations enforced by building constraints, certain requirements of EN 115-1:2017 cannot be fully met. This standard shall only be used when replacing existing escalators/moving walks where structural constraints within an existing building make the installation of fully EN115-1:2017 compliant escalators/moving walks impossible. The escalator/moving walk installer must liaise with the customer and recommend altering the building structure in the first instance and deviations from EN115-1 should only be considered as a last resort. This standard addresses a number of these constraints, gives requirements for alternative solutions and covers:  the replacement of an existing escalator/moving walk by a new one in an existing building. This standard does not cover:  construction and installation of a new escalator / moving walk in  an existing building, which is not replacing an existing escalator/moving walk;  replacement or modifications of some parts of existing escalator/moving walk, e.g. intruss modernization;  major modifications of existing escalator/moving walk, e.g. change of the location (see EN 115-1:2017, Annex L);  other applications outside of the scope of EN 115-1:2017

Info

Stage Date

2025-11-20

Stage Code

40.60.0000 - Draft

Sector

Mechanical Engineering

Technical Committee

TE 34

espa-banner