ΕΛΟΤ EN 13786+A1
Automatic change-over valves having a maximum outlet pressure of up to and including 4 bar with a capacity of up to and including 100 kg/h, and their associated safety devices for butane, propane or their mixtures
Abstract
This European Standard defines the constructional and operational characteristics, the safety requirements and test methods, and the marking of automatic change over devices with a capacity of less than or equal to 100 kg/h and having a maximum regulated pressure of less than or equal to 4 bar for butane, propane or their mixtures only in the vapour phase. NOTE 1 bar = 105 Pa. Liquefied gases containing methylacetylene and propadiene are not covered by this standard. This European Standard also covers safety devices likely to be fitted onto automatic change over devices. The characteristics of these devices are given in annex A. The requirements of this European Standard generally cover designs where regulation is in one stage, using a single diaphragm. These requirements do not exclude designs using more than one diaphragm, provided that these diaphragms are integrated in a single automatic change over devices complying with the requirements of this European Standard. For specific uses in caravans and leisure vehicles, the automatic change over devices function may also be carried out by an assembly of regulators, forming a "automatic change over devices system" as defined in 3.1.2. This standard covers such an assembly as follows: - special requirements for the manufacture, adjustment and operation of regulators forming a automatic change over devices system, as well as the corresponding test methods are given in annex B; - except for these special requirements, and unless otherwise stated, constructional and performance characteristics given in the body of the standard are also applicable to the devices in annex B. The requirements apply generally to automatic change over device used in locations where the temperature likely to be reached during use is between -20 °C and +50 °C. When the devices are used at temperatures outside this range they shall comply with special requirements defined in annex C. This standard does not include the installation rules
Info
The standard has been withdrawn
Publication Date
2009-01-21
Withdrawal Date
2013-12-18
Greek Title
Αυτόματοι μεταγωγείς με μέγιστη πίεση εξόδου έως και 4 bar, με παροχή έως και 100 Kg/h και οι σχετικές διατάξεις ασφάλειας, για βουτάνιο, προπάνιο ή μείγματά τους
English Title
Automatic change-over valves having a maximum outlet pressure of up to and including 4 bar with a capacity of up to and including 100 kg/h, and their associated safety devices for butane, propane or their mixtures
Standard Stage
Techincal Body
TE 84Replaced by
ΕΛΟΤ EN 16129:2013Replaces
EΛΟΤ EN 13786:2005Related Documents